UK & Ireland

Multi-Function Amplifier

The multi-function amplifier with an all-in-one design

Calculation Function

[Addition mode]
SETTING EXAMPLE 1
(thickness measurement)

SETTING EXAMPLE 1(thickness measurement)


SETTING EXAMPLE 2
(width measurement)

SETTING EXAMPLE 2(width measurement)

[Subtraction mode]
SETTING EXAMPLE 1(Measurement of height difference)

SETTING EXAMPLE 1(Measurement of height difference)


SETTING EXAMPLE 2
(Measuring tilt)

SETTING EXAMPLE 2(Measuring tilt)

Internal calculations are possible for all kinds of applications.
This device is equipped with an all-in-one add/subtract function that focuses PLC data and reduces programming hours.

NEW MODE – Thickness Calibration Function Included

3-step easy calibration

With conventional devices, calibration had to be conducted on every individual sensor head, however, the IL Series has a
dedicated mode that allows calibration to be completed in 3 simple steps.

Step1

Step1

Bring the target close to one sensor head and input the thickness data, then push the set button.

Step2

Step2

Bring the same target used in Step 1 close to the opposing sensor head and push the set button.

Step3

Step3

Insert a target thicker than the target used in Step 2. Input the thickness data. Then pushing the set button completes calibration.


When bringing the target closer to the sensor head in Steps 1 and 2, you are compensating for the misalignments that occur during installation.
To set, you can begin with either one of the sensor heads.

Height difference count filter function included

This function identifies step edges automatically and delivers one-shot output for each step. Create settings for count and seam detection applications easily, without the programming hours.

Height difference count filter function included