| Type |
Multi range
| Negative pressure
| Positive pressure
|
| Model |
NPN |
AP-C30W
| AP-C31W
| AP-C33W
|
| PNP |
AP-C30WP
| AP-C31WP
| AP-C33WP
|
| Response time |
2.5, 5, 100, or 500 ms (selectable) |
|  |
 |
 |
 |
 |
| Rated pressure |
Negative
pressure mode |
Positive
pressure mode |
Compound
pressure mode |
0 to -29.9 inchHg |
0 to 145.0 Psi |
| 0 to -29.9 inchHg |
0 to 29.5 inchHg |
29.9 to -29.9 inchHg |
| Proof pressure |
500kPa |
500kPa |
1.5MPa |
| Pressure type |
Gauge pressure |
| Fluid types |
Air or non-corrosive gases |
| Resolution |
Multi range:
Negative: 0.1 inchHg |
Multi range:
Positive: 0.1 inchHg |
Multi range:
Compound: 0.1 inchHg |
Normal mode:
0.1 inchHg
Focus mode:
0.01 inchHg |
Normal mode:
0.2 Psi
Focus mode:
0.02 Psi |
| Repeatability |
± 0.2% of F.S. |
| Control output |
NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (N.O. or N.C. selectable) |
| Analog output |
1 to 5 V with load impedance of 1 kΩ max (or zero-shift input selectable) |
| Power supply |
12 to 24 VDC ±10% with ripple (p–p) of 10% max. |
| Ambient temperature |
0 to 50ºC (32 to 122ºF), No condensation |
| Relative humidity |
35 to 85%, No condensation |
| Vibration resistance |
10 to 55 Hz, 0.06" 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively |
| Material |
Front housing: Polysulfone, Rear housing: PBT,
Front seat: Polycarbonate, Pressure port: Zinc die-casting |