Separate Amplifier Type Pressure SensorAP-40 series

AP-41M

Sensor Head: Negative pressure Type, -101.3 kPa

SPECIFICATIONS

Select Language

Model

AP-41M

Application

Gauge pressure

Type

Negative pressure

Rated pressure

0 to -101.3 kPa

Fluid type

Air, non-corrosive gasses

Temperature characteristic

±2% of F.S. (When the temperature varies from 25°C)

Pressure port

M3 male threaded

Environmental resistance

Pressure resistance

500 kPa

Ambient temperature

0 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 4 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 10 times in each of X, Y and Z directions, total of 60 times

Material

Case: PBT, Screw: SUS303, Cable: PVC

Weight

Approx. 68 g (including cable)