SJ-R Static Elimination Specifications
Model SJ-R036 SJ-R060 SJ-R084 SJ-R108 SJ-R132 SJ-R156
Ion generation method Corona discharge
Structure Shock-proof, resistance-coupled
Voltage application method
/appliedvoltage
Pulse AC method/±7,000 V
Ion balance control method I.C.C. method
Ion balance (1).(2) ±30 V
Operating distance 50 to 2,000 mm
Primary features • Condition alarm output, ion level alarm output, alarm output
• Ion balance adjustment feature (via remote control)
• Connection for monitor with power supply
Air purge connection port M5
Air purge pressure 0.2 MPa or less
Electrode probes Tungsten or silicon
Enclosure ABS resin
Control input NPN open collector or non-voltage contact signal
Output NPN type photorelay: max. 100 mA (40 V or less)
Power supply voltage DC 24 to 36 V ±10%
Current consumption 250 mA (at DC 24 V)/150 mA (at DC 36 V)
Operating
ambient temperature
0 to +50°C (32 to 122 °F),No freezing
Operating
ambient humidity
35% to 85% RH (non-condensing)
Models that ship with silicon electrode probes installed are indicated by a "C" at the end of their model number.
1. Value measured at operating distances of 50 mm (30 Hz), 600 mm (10 Hz), 1,500 mm (1 Hz); an operating ambient temperature between 0 and +50°C; an operating ambient humidity between 35% and 85% RH; and under a 0.3 m/s downflow.
2. SJ-R132W/136W is measured at an installation distance of 600 mm (10 Hz), 1,500mm (1 Hz), 0 - ±50 °C,and 35-65% RH. (Please contact KEYANCE separately regarding the ion balance for 50mm installation.)
(Note 1) A 10 pin I/O cable or 10 to 10 pin modular cable is required to make the connection.
(Note 2) The SJ-R036W requires a 6 to 8 pin modular cable to connect the bar and the controller.Contact your nearest Sales Office for information about CE compliance.
Tools : 0 0Save to MyFavorites0 0My Downloads0 0Email a Friend0 0Print Page0
Related Information Topics
Practical Static Electricity Q&A Book Vol.4  
Counter Measures Against Electrostatic Damage
Practical Static Electricity Q&A Vol.3  
Measures Against Production Line Problems
New! Ultimate Sensor Selection Guide  
A Must Have for Any Engineer!! 38 full colour pages. Includes 27 new models.
General Catalog  
Just released Get your copy today.
Recommended Downloads
Related Product Downloads

Static Eliminator/Ioniser

Product Catalogs Instruction Manuals Technical Guide 2D CAD Data 3D CAD Data
High-speed Clean Air Barrier Static Eliminator SJ-G Series NEW
Controller-integrated static eliminator SJ-R Series
Ultra high speed Static elimination blower SJ-F300 Series NEW
Super compact static elimination blower SJ-F010 Series
Spot type high-speed static eliminator SJ-SW Series
High-performance Micro Ioniser SJ-M Series NEW
Product catalogs and manuals include both elimination head and controller information.
READ BEFORE BUYING!
Request SJ-R Series price information.
See how Keyence will ship your order the day it's received
Try the SJ-R Series free of charge.
Let the Keyence Experts answer your questions.
HOME PRODUCTS APPLICATIONS DOWNLOADS SUPPORT/SERVICES NEWS/TOPICS COMPANY CONTACT
America Canada(English) Germany France Italy United Kingdom China Taiwan Malaysia Singapore Thailand Korea Japan