SJ-R Static Elimination Specifications
| Model |
SJ-R036 |
SJ-R060 |
SJ-R084 |
SJ-R108 |
SJ-R132 |
SJ-R156 |
| Ion generation method |
Corona discharge |
| Structure |
Shock-proof, resistance-coupled |
Voltage application method
/appliedvoltage |
Pulse AC method/±7,000 V |
| Ion balance control method |
I.C.C. method |
| Ion balance (1).(2) |
±30 V |
| Operating distance |
50 to 2,000 mm |
| Primary features |
• Condition alarm output, ion level alarm output, alarm output
• Ion balance adjustment feature (via remote control)
• Connection for monitor with power supply |
| Air purge connection port |
M5 |
| Air purge pressure |
0.2 MPa or less |
| Electrode probes |
Tungsten or silicon |
| Enclosure |
ABS resin |
| Control input |
NPN open collector or non-voltage contact signal |
| Output |
NPN type photorelay: max. 100 mA (40 V or less) |
| Power supply voltage |
DC 24 to 36 V ±10% |
| Current consumption |
250 mA (at DC 24 V)/150 mA (at DC 36 V) |
Operating
ambient temperature |
0 to +50°C (32 to 122 °F),No freezing |
Operating
ambient humidity |
35% to 85% RH (non-condensing) |
Models that ship with silicon electrode probes installed are indicated by a "C" at the end of their model number.
1. Value measured at operating distances of 50 mm (30 Hz), 600 mm (10 Hz), 1,500 mm (1 Hz); an operating ambient temperature between 0 and +50°C; an operating ambient humidity between 35% and 85% RH; and under a 0.3 m/s downflow.
2. SJ-R132W/136W is measured at an installation distance of 600 mm (10 Hz), 1,500mm (1 Hz), 0 - ±50 °C,and 35-65% RH. (Please contact KEYANCE separately regarding the ion balance for 50mm installation.)
(Note 1) A 10 pin I/O cable or 10 to 10 pin modular cable is required to make the connection.
(Note 2) The SJ-R036W requires a 6 to 8 pin modular cable to connect the bar and the controller.Contact your nearest Sales Office for information about CE compliance.
|