Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Fully Operational with Expanded Resources
          Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
          1. Home
          2. Products
          3. Measurement Sensors
          4. Laser Displacement Sensors
          5. Surface Scanning Laser Confocal Displacement Meter
          6. Specs

          Surface Scanning Laser Confocal Displacement Meter

          LT-9000 series

          Select Language

          Model

          LT-9501H

          LT-9501HSO(5654)

          LT-9001HSO(5655)

          Measuring unit compatibility

          Measuring units are interchangeable without factory recalibration.

          Display

          Minimumdisplayable unit

          0.1 µm*1, 1 µm2, 0.01 °

          0.1 µm*1

          Display range

          ±9,999.99 µm, ±999,999 µm2, 9,999.99 °

          ±9,999.99 µm

          Microscope function

          Available

          Display cycle

          10 times/sec.*2

          Terminal block

          Analogue output

          ±10 V x 2 outputs, output impedance: 100 Ω

          Timing input

          Non-voltage input

          Reset input

          Auto-zero input

          Monitor dedicated power supply

          24 VDC*3

          Control I/O

          Judgment mode

          3-step limits output

          For OUT1 and OUT2, and NPN open collector output*4

          Binary mode

          Binary output

          Measured data output (21 bits), OUT1/OUT2/PROFILE selectable
          NPN open collector output*4

          Strobe output

          NPN open collector output*4

          Binary selector output

          Binary selection input

          Non-voltage input*4

          Stability output

          NPN open collector output

          Laser remote input

          Non-voltage input

          Program switching input

          Non-voltage input x 3 inputs

          RS-232C interface

          Measured data output and control I/O (Selectable up to baud rate 115200 bps.)

          Video output

          NTSC compliant (PIN connector)

          Main functions

          Displacement mode

          Distance measurement, Transparent objectthickness measurement, Angle measurement,Relative angle measurement, Surface selection,Dark-out, Mask, Trend graph display, and Scanwidth/interval change*5

          Distance measurement,
          Transparent object thickness measurement,
          Surface selection, Dark-out, Mask, Trend
          graph display,
          and Scan width/interval change*6

          Profile mode

          Area selection (Average, Maximum,
          Minimum, Maximum-to-minimum, Area)
          Area calculation, Scan width/interval
          change, Dark-out, Smoothing, Averaging,
          and Profile data output*6

          *6

          Common

          Light intensity accumulation, Microscope (LT-9501H, LT-9501HSO (5654) only),
          Tolerance judgement, 8-program registration, Calibration, Averaging, Hold modes,
          Auto-zero, and interface language selection

          Rating

          Power voltage

          100 to 240 VAC ±10 %, 50/60 Hz

          Power consumption

          110VA or less

          Environmental resistance

          Pollution degree

          2

          Overvoltage category

          II

          Ambient temperature

          0 to +35 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 2.4 kg

          *1 Display changes every ±0.3 µm.
          *2 Varies depending on the setting
          *3 Dedicated power supply for the monitor specified by KEYENCE.
          *4 Select either the Limits mode or the Binary mode.
          *5 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.
          *6 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)
          The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.
          The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.

          Model

          LT-9011M

          LT-9011

          LT-9031M

          LT-9031

          Type

          High-accuracy

          Long-range

          Measurement range

          ±0.3 mm

          ±1.0 mm

          Reference distance

          6 mm

          30 mm

          Light source

          Type

          Red semiconductor laser

          Wavelength

          655 nm

          Output

          170 µW (IEC 60825-1) /3.0 µW (FDA (CDRH) Part 1040.10)

          Laser Class

          Class IIa Laser Product (FDA (CDRH) Part 1040.10)
          Class 1 Laser Product (IEC 60825-1)

          Spot diameter

          Approx. ø2 µm

          Approx. ø7 µm

          Scan width/interval

          0 to 1,100 µm (6 steps) /1 to 10 µm (4 steps)

          0 to 560 µm (6 steps) /1 to 8 µm (4 steps)

          Resolution

          0.3 µm*1

          Linearity

          ±0.5 % of F.S.*1

          ±0.3 % of F.S.*1

          Sampling cycle

          640 µs to 356 ms (14 steps)*2

          640 µs to 187 ms (14 steps)*2

          Display

          Minimumdisplayable unit

          0.1 µm*3, 1 µm2, 0.01 °

          0.1 µm*3

          Display range

          ±9,999.99 µm, ±999,999 µm2, 9,999.99 °

          ±9,999.99 µm

          Microscope function

          Available

          Available

          Display cycle

          10 times/sec.*4

          Terminal block

          Analogue output

          ±10 V x 2 outputs, output impedance: 100 Ω

          Timing input

          Non-voltage input

          Reset input

          Auto-zero input

          Monitor dedicated power supply

          24 VDC*5

          Control I/O

          Judgment mode

          3-step limits output

          For OUT1 and OUT2, and NPN open collector output*6

          Binary mode

          Binary output

          Measured data output (21 bits), OUT1/OUT2/PROFILE selectable
          NPN open collector output*6

          Strobe output

          NPN open collector output*6

          Binary selector output

          Binary selection input

          Non-voltage input*6

          Stability output

          NPN open collector output

          Laser remote input

          Non-voltage input

          Program switching input

          Non-voltage input x 3 inputs

          RS-232C interface

          Measured data output and control I/O (Selectable up to baud rate 115200 bps.)

          Video output

          NTSC compliant (PIN connector)

          Microscope function

          Function presence/absence

          Compatible

          N/A

          Compatible

          N/A

          Field of view

          1.3 mm x 1.05 mm

          2.5 mm x 2.0 mm

          Type

          Available

          Unavailable

          Available

          Unavailable

          Illumination light source

          Infrared LED
          (wavelength: 870 nm)

          Infrared LED
          (wavelength: 870 nm)

          Main functions

          Displacement mode

          Distance measurement, Transparent objectthickness measurement, Angle measurement,Relative angle measurement, Surface selection,Dark-out, Mask, Trend graph display, and Scanwidth/interval change*7

          Distance measurement,
          Transparent object thickness measurement,
          Surface selection, Dark-out, Mask, Trend
          graph display,
          and Scan width/interval change*8

          Profile mode

          Area selection (Average, Maximum,
          Minimum, Maximum-to-minimum, Area)
          Area calculation, Scan width/interval
          change, Dark-out, Smoothing, Averaging,
          and Profile data output*8

          *8

          Common

          Light intensity accumulation, Microscope (LT-9501H, LT-9501HSO (5654) only),
          Tolerance judgement, 8-program registration, Calibration, Averaging, Hold modes,
          Auto-zero, and interface language selection

          Temperature characteristics (20 to 30°C)

          ±0.5% of F.S.

          ±0.25% of F.S.

          Rating

          Power voltage

          100 to 240 VAC ±10 %, 50/60 Hz

          Power consumption

          110VA or less

          Environmental resistance

          Pollution degree

          2

          Overvoltage category

          II

          Ambient light

          Incandescent lamp/fluorescent lamp: 10,000 lux max.

          Ambient temperature

          0 to +35 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 400 g

          Approx. 500 g

          *1 The value when the measurement target is a mirrored surface object measured in displacement mode, scan width/interval 120 µm/2 µm, and 8-times average
          *2 Sampling cycle differs according to the manufacturing variation of individual measuring units. The value when the FINE mode is set to OFF.
          *3 Display changes every ±0.3 µm.
          *4 Varies depending on the setting
          *5 Dedicated power supply for the monitor specified by KEYENCE.
          *6 Select either the Limits mode or the Binary mode.
          *7 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.
          *8 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)
          The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.
          The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.

          Model

          LT-C2*1

          LT-C10*1

          Cable length

          2 m

          10 m

          Weight

          Approx. 200 g

          Approx. 700 g

          *1 Up to 3 cables can be connected with a total maximum length of 20 m.

          Measurement Library

          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE (UK) Ltd Avebury House, 219-225 Avebury Boulevard, Milton Keynes MK9 1AU, U.K.
          Phone: +44 (0) 1908-696-900
          E-mail: ukinfo@keyence.co.uk
          Career Opportunities: KEYENCE Career Site

          Measurement Sensors