          Model

          IB-01

          IB-05

          IB-10

          IB-30

          Light source

          Wavelength

          660 nm (Visible light semiconductor laser)

          Laser Class

          Class 1 Laser Product (IEC 60825-1, FDA (CDRH) Part 1040.10*1)

          Mounting distance

          0 to 2,000 mm

          0 to 300 mm

          Measurement range

          ø1 mm (Installation distance 0 to 300 mm)
          ø1 to 2.5 mm (Installation distance 300 to 2,000 mm)

          5 mm

          10 mm

          30 mm

          Sampling cycle

          12,500 times/sec. (80 µs)

          Minimum detectable object

          ø8 µm (Installation distance 0 to 300 mm)
          ø8 to 50 µm (Installation distance 300 to 2,000 mm)*2

          ø0.05 mm*2

          ø0.1 mm*2

          ø0.2 mm*2

          Repeatability

          5 µm (distance 0 to 300 mm)*3

          5 µm*3

          10 µm*3

          Temperature characteristics

          ±0.2 % of F.S./°C*4

          ±0.1 % of F.S./°C (±5 µm)*4

          ±0.1 % of F.S./°C (±10 µm)*4

          ±0.1 % of F.S./°C (±30 µm)*4

          Operation indicator

          Laser emission warning indicator: green LED

          Environmental resistance

          Ambient light

          Incandescent lamp: 5,000 lux, Solar light: 10,000 lux

          Incandescent lamp: 5,000 lux, Solar light: 5,000 lux

          Incandescent lamp: 10,000 lux, Solar light: 10,000 lux

          Ambient temperature

          0 to +40 °C (No freezing)

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

          Material

          Case

          PBT

          Galvanised die cast

          Lens cover

          Glass

          Cable

          PVC (2 m)

          Weight

          Approx. 140 g

          Approx. 180 g

          Approx. 220 g

          Approx. 510 g

          *1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
          *2 Value when measuring the target (white diffuse object) at the middle of the transmitter and receiver position, and at the centre of the measurement range.
          *3 When distance between transmitter and receiver is set to 300 mm, and light is half-shielded at a position 150 mm from receiver. Deflection width (±2σ) when sampled for 30 seconds with an average
          number of times set to 64 times.
          *4 When distance between transmitter and receiver is set to 100 mm and full light is received.

          Model

          IB-1000

          IB-1500

          IB-1050

          IB-1550

          Type

          DIN rail mount

          Panel mount

          DIN rail mount

          Panel mount

          Main unit/Expansion unit

          Main unit

          Expansion unit

          Head compatibility

          Yes

          Display

          Display resolution

          0.01 %, 0.1 %, 1 % (switchable)

          Display range

          –99.999 to 99.999, –99.99 to 99.99, –99.9 to 99.9, –99 to 99 (switchable)

          Digital display method

          Dual 7-segment display, Upper level: 5 red digits, Lower level: 5 green digits

          Dual 7-segment display, Upper level: 2-colour (green/red), 5 digits, Lower level: 5 green digits

          Dual 7-segment display, Upper level: 5 red digits, Lower level: 5 green digits

          Dual 7-segment display, Upper level: 2-colour (green/red), 5 digits, Lower level: 5 green digits

          Operation indicator

          Judgment indicator: 2-colour (green/red) LED (HI, GO, LO), Bank indicator: Green LED x 4,
          Laser emission warning indicator: Green LED, Others: Green LED x 8, red LED x 3

          Analogue output voltage

          ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100Ω*1

          No

          Analogue current output

          4 to 20 mA Maximum load resistance 350 Ω*1

          Control Input

          Bank switch input, zero shift input

          Non-voltage input*2

          Control input

          Zero-shift input

          Laser emission stop input

          Timing input

          Reset input

          Adjust input

          Control output

          Judgment output (check output)

          Open collector (NPN/PNP switchable, N.O./N.C. switchable)*3

          Power supply

          Power consumption

          1,950 mW or less (at 30 V, 65 mA max.)*4

          2,100 mW or less (at 30 V, 70 mA max.)*4

          1,950 mW or less (at 30 V, 65 mA max.)*4

          2,100 mW or less (at 30 V, 70 mA max.)*4

          Rating

          Power voltage

          10 to 30 VDC, including Ripple (P-P) 10 %, Class 2 or LPS

          Supplied from main unit

          Environmental resistance

          Pollution degree

          2

          Ambient temperature

          -10 to +50 °C (No condensation or freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

          Material

          Case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

          Weight

          Approx. 150 g

          Approx. 170 g

          Approx. 140 g

          Approx. 165 g

          *1 ±5 V, 1 to 5 V, 0 to 5 V, or 4 - 20 mA should be selected.
          *2 The four external input wires are assigned with desired inputs.
          Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
          Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
          *3 Rated NPN open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
          Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 2 V or less
          *4 The power consumption with slave units installed is the total of each amplifier unit's power consumption.