Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Ultra-High-speed, High-accuracy Optical MicrometerLS-9000 series

          LS-9030M

          Head: Standard model with monitor camera

          SPECIFICATIONS

          Select Language

          Model

          LS-9030M*1

          Type

          Head: Standard model

          Measurement range

          0.3 mm (0.08 mm) to 30 mm

          Smallest detectable object

          0.3 mm (0.08 mm)

          Transmitter/receiver distance

          160 ±40 mm

          Repeatability

          ±0.1 µm*2

          Measurement accuracy

          ±2 µm*3

          Sampling cycle

          16,000 samples/sec.*4

          Transmitter/receiver direction and position detection

          Detection area

          20 x 24 mm

          Smallest detectable object

          0.3 mm

          Repeatability

          ±0.2 mm*5

          Sampling cycle

          4,000 samples/sec.

          Light source

          InGaN green LED

          Monitor camera

          Provided

          Environmental resistance

          Enclosure rating

          IP67 (including connector)

          Ambient light

          Incandescent lamp/Fluorescent lamp: 3,000 lux or lower

          Ambient temperature

          0 to +50 °C

          Relative humidity

          20 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          15 G/6 ms

          Material

          Aluminum

          Weight

          Transmitter: Approx. 440 g
          Receiver: Approx. 500 g
          Base: Approx. 430 g

          *1 The values in brackets are measured in ultra-thin mode. For details on the accuracy of ultra-thin mode, contact the nearest KEYENCE office.
          *2 A ±2σ margin of error when measuring a ø10 mm rod in the centre of the measurement area using outer diameter mode with the average measurement number set as 2,048 times.
          *3 Margin of error when a moving ø10 mm rod is measured in the 10 mm x 20 mm measurement area using outer diameter mode.
          *4 The sampling cycle is changed by the number of OUT set, and by the use of the mutual interference prevention function.
          *5 A ±2σ margin of error when measuring the position of a ø10 mm rod in the centre of the measurement area with the average measurement number set as 512 times.