Recent Searches
    Series ()
      Models ()
        Keywords

          Safety Light CurtainGL-R series

          GL-R48H

          Main Unit, Hand-protection Type, 48 Optical Axes

          SPECIFICATIONS

          Select Language

          Model

          GL-R48H

          Detection capability

          ø25 mm

          Beam axis spacing/Lens diameter

          20 mm / ø5

          Detecting distance

          0.2 to 15 m*1

          Effective aperture angle

          Max. ±2.5° (When operating distance is 3 m or more)

          Light source

          Infrared LED (870 nm)

          Response time (OSSD) (ms)

          Wire synchronisation, One-line or
          Optical synchronisation system (Channel 0)

          ON→OFF

          9.6

          OFF→ON

          53.2*2

          All blocked→ON

          75.2*3

          Optical synchronisation system
          (Channel A or B)

          ON→OFF

          13.6

          OFF→ON

          59.3*2

          All blocked→ON

          91.4*3

          Detection mode

          Turns on when no interruptions are present in the detection zone

          Synchronisation between the transmitter and receiver

          Optical synchronisation or Wire synchronisation (Determined by wiring)

          Light interference prevention function

          Prevents mutual interference in up to two GL-R systems.
          Optical synchronization: prevented by Channel A and B with setting switch
          Wire synchronization: prevented automatically

          Control output
          (OSSD output)

          Output

          2 transistor outputs. (PNP or NPN is determined by the cable type)

          Max. load current

          500 mA*4

          Residual voltage (during ON)

          Max. 2.5 V (with a cable length of 5 m)

          OFF state voltage

          Max. 2.0 V (with a cable length of 5 m)

          Leakage current

          Max. 200 µA

          Max. capacitive load

          2.2 µF

          Load wiring resistance

          Max. 2.5 Ω

          Supplemental output
          (Non-safety-related output)

          AUX

          transistor outputs. (PNP or NPN is determined by the cable type)
          Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m)

          Error output

          Muting lamp output

          Incandescent lamp (24 VDC, 1 to 5.5 W)
          LED lamp (load current: 10 to 230 mA) can be connected.

          External input

          When using a PNP output cable

          EDM input
          Wait input
          Reset input
          Muting input 1, 2
          Override input

          ON voltage: 10 to 30 V
          OFF voltage: Open or 0 to 3 V
          Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

          When using an NPN output cable

          ON voltage: 0 to 3 V
          OFF voltage: Open or 10 V or more
          Up to the power voltage
          Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

          Rating

          Power voltage

          24 VDC ±20%, ripple (P-P) 10% or less, Class 2

          Power supply

          Current
          consumption
          (Max.) (mA)

          Transmitter

          68

          Receiver

          79

          Protection circuit

          Reverse current protection, short-circuit protection for each output, surge protection for each output

          Approved standards

          EMC

          EMS

          IEC61496-1, EN61496-1, UL61496-1

          EMI

          EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

          Safety

          IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
          IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
          IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
          EN ISO13849-1:2015 (Category 4, PLe)
          UL508
          UL1998

          Environmental resistance

          Enclosure rating

          IP65/IP67 (IEC60529)

          Overvoltage category

          II

          Ambient light

          Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less

          Operating ambient temperature

          -10 to +55 °C (No freezing)

          Storage temperature

          -25 to +60 °C (No freezing)

          Operating relative humidity

          15 to 85 % RH (No condensation)

          Storage relative humidity

          15 to 95 % RH

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Material

          Main unit case

          Aluminium

          Upper case/lower case

          Nylon (GF 30%)

          Front cover

          Polycarbonate, SUS304

          Weight

          Transmitter

          1330 g

          Receiver

          1340 g

          *1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m.
          *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will
          be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
          *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the
          transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation,
          the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then
          determines the clear or blocked.
          *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA.