Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          1. Home
          2. Products
          3. Safety
          4. Type 4 safety light curtain
          5. Safety Light Curtain
          6. Models
          7. Main Unit, General-purpose Type, 26 Optical Axes

          Safety Light CurtainSL-C series

          Main Unit, General-purpose Type, 26 Optical Axes

          SL-C26L

          [Discontinued model]

          This model has been discontinued.

          Recommended Replaceable Products
          To contact us:

          SPECIFICATIONS

          Select Language

          Model

          SL-C26L

          Effective aperture angle

          Max. ±2.5 ° (when operating distance is at least 3 m)

          Response time

          15 ms *1

          Light source

          Infrared LED (850 nm)

          Operation mode

          Turned on when light is being applied to all optical axes (excluding when the blanking function is used)

          Detection capability

          ø45 mm*2

          No. of beam axes

          26

          Detection zone

          1000 mm

          Protection area

          1085 mm

          Detectingdistance

          0.3 to 9 m

          Beam axis interval

          40 mm

          Lens diameter

          ø5mm

          OSSD output

          Output type

          2 outputs each for PNP and NPN, Can be switched using the connection connector cable

          Max. load current

          300 mA *3

          OFF-state voltage

          2.5 V (with a cable length of 7 m)

          Leakage current

          100 µA maximum*4

          Max. capacitive load

          2.2 µF (with a load resistance of 100 Ω)

          Load wiring resistance

          2.5 Ω maximum*5

          Approved standards

          EMC

          EMS

          UL61496-1

          EMI

          FCC Part15 Class A

          Safety

          UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508

          Current consumption

          Transmitter

          70 mA

          Receiver

          77 mA

          Rating

          Power voltage

          24 VDC ±10 %, Ripple (P-P) 10 % or less

          Environmental resistance

          Enclosure rating

          IP65 (IEC60529)

          Ambient light

          Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less

          Operating ambient temperature

          -10 to +55 °C (No freezing)

          Storage temperature

          -10 to +60 °C (No condensation

          Operating relative humidity

          35 to 85 % RH (No condensation)

          Storage relative humidity

          35 to 95 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Weight

          Transmitter

          Approx 660 g

          Receiver

          Approx 725 g

          *1 OFF→ON return time is 125 ms.
          *2 If the SL-CL Series, which has a minimal detection object diameter of 45 mm, is used in conjunction with the SL-R12EX, the blanking function and muting function cannot be used.
          *3 Note the derating illustrated in the graph to the right when using PNP output.