Recent Searches
    Series ()
      Models ()
        Keywords

          Safety Light CurtainSL-V series

          SL-V22L

          Main Unit, General-purpose Type, 22 Optical Axes

          SPECIFICATIONS

          Select Language

          Model

          SL-V22L

          Detection capability

          ø45 mm

          Beam axis spacing/Lens diameter

          40 mm/ø5 mm

          Effective aperture angle

          Max. ±2.5 ° (When operating distance is 3 m or more)

          Working distance

          0.1 m to 9.0 m (detection height of 1,260 mm or l ess)
          0.1 m to 7.0 m (detection height of 1,400 mm or more)

          Response time (ms)

          ON→OFF

          8.9*1

          OFF→ON

          48.9*1

          Light source

          Infrared LED (850 nm)

          Operation mode

          Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)

          OSSD output

          Output

          2 outputs each for PNP and NPN. Can be changed by using the connector cable.

          Max. l oad current

          500 mA*2

          Residual vol tage (during ON)

          Max. 2.5 V (with a cable length of 7 m)

          Leakage current

          Max. 100 µA*3

          Max. capacitive load

          2.2 µF (with a load resistance of 100 Ω)

          Load wiring resistance

          Max. 2.5 Ω*4

          Non safety-rel atedoutput

          AUX

          Output with automatic PNP/NPN switching function, 50 mA max.

          Interlock-reset-ready output

          Alarm output

          Clear/blocked output

          State information output 1, 2

          Muting lamp output

          Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected

          Input

          EDM input

          Short-circuit current 10 mA

          Wait input

          Short-circuit current 2.5 mA

          Reset input

          Muting input 1, 2

          Override input

          Protection circuit

          Reverse current protection, short-circuit protection for each output, surge protection for each output

          Approved standards

          EMC

          EMS

          IEC61496-1, EN61496-1, UL61496-1

          EMI

          EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

          Safety

          IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
          IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
          IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
          UL508
          UL1998

          Rating

          Power voltage

          24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less

          Current consumption (mA)

          When the Centre indicator is ON

          Transmitter

          93*6

          Receiver

          81*6

          When the Centre indicator is OFF

          Transmitter

          84*6

          Receiver

          70*6

          Environmental resistance

          Enclosure rating

          IP65 (IEC60529)

          Overvoltage category

          II

          Ambient light

          Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

          Operating ambient temperature

          -10 to +55 °C (No freezing)

          Storage temperature

          -25 to +60 °C (No freezing)

          Operating relative humidity

          15 to 85 % RH (No condensation)

          Storage relative humidity

          15 to 95 % RH

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Material

          Main unit case

          Aluminium

          Upper case/lower case

          Zinc die-cast

          Front cover

          Polycarbonate, SUS304

          Weight

          Transmitter

          600 g

          Receiver

          625 g

          *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit.
          e.g. When connecting the SL-V32H (32 beam axes), SL-V24H (24 beam axes), andSL-V12L (12 beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6ms respectively, and the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
          *2 When used under ambient temperature between 45 to 55 °C, the maximum should not exceed 300 mA.
          *3 Applies to situations when power is either off or disconnected.
          *4 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable) must be 2.5 Ω or less to ensure operations. If using the NPN output with a cable length of 15 m or longer, and the load current consumption is 200 mA or more, the wire resistance must be 1.0 Ω or less.
          *5 When used under ambient temperature between 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED lamps (load current: 10 to 100 mA).
          *6 The current consumption of the transmitter increases by 10 mA and decreases on the receiver by 10 mA when the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short circuited if the fol lowing additional condition is met. (The total consumption of both transmitter and receiver is fixed.)
          In the case where the PNP output type cabl e is used, the condition is that OSSD stays in the OFF state.
          In the case where the NPN output type cable is used, the condition is that OSSD stays in the ON state.