          Digital Fibre Optic SensorsFS-N40 series

          FS-N41C

          Fibre Amplifier, M8 Connector Type, Main Unit

          SPECIFICATIONS

          Select Language

          Model

          FS-N41C*1

          Type

          M8 Connector*2

          Main unit/expansion unit

          Main unit

          Number of control outputs

          2*3

          Number of external inputs

          1*3

          Light source LED

          Transmitter side: Red, four-element LED (wavelength 660 nm)

          Response time

          23 µs (S-HSPD*4)/50 µs (HSPD*5) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)

          Control output

          Open-collector, 30 V or less 100 mA or less per output,
          100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit)
          Residual voltage
          NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA)
          PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA)

          External input

          Input time 2 ms (ON) / 20 ms (OFF) or longer*6

          Protection circuit

          Protection against reverse power connection, output overcurrent, output surge, and reverse output connection

          Mutual interference prevention

          S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units
          (The mutual interference prevention values are twice those shown here when Double is set.)

          Power supply

          Power voltage

          10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*7

          Current consumption

          During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
          ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V)
          ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8

          Environmental resistance

          Ambient light

          Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less

          Operating ambient temperature

          -20 °C to +55 °C (no freezing)*9

          Vibration resistance

          10 to 55 Hz; double amplitude 1.5 mm; 2 hours each for X, Y, and Z axes

          Shock resistance

          500 m/s2 ; 3 times each for X, Y, and Z axes

          Case material

          Main unit and cover: polycarbonate

          Weight

          Approx. 25 g

          *1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is supported.
          *2 Ensure the cable length is 30 m or less for the M8 connector type.
          Ensure the cable length is 20 meters or less when connecting by way of IO-Link.
          *3 Output 2 and the external input are selectable.
          *4 Restrictions when S-HSPD is selected
          Output 2 of dual output types is fixed to OFF.
          IO-Link communication cannot be used.
          Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.
          Output timer, Limit Detection, and Display Gain cannot be used.
          FULL cannot be selected for the ECO function.
          *5 Restrictions when HSPD is selected
          Display Gain cannot be used.
          *6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.
          *7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.
          *8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.
          *9 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C.
          When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units.
          The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface.
          Exercise special care when installing the product in an airtight space.