          Multi-Purpose Digital Laser SensorLV-N series

          LV-N12P

          Amplifier, Cable, Expansion unit, PNP

          SPECIFICATIONS

          Select Language

          Model

          LV-N12P

          Type

          2 output

          Output

          PNP

          Cable/connector

          Cable

          Main/Expansion unit

          Expansion unit

          I/O

          Control outputs

          2 output

          External input

          1 input

          Monitor output

          None

          Response time

          80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer,
          Timer duration selectable: 1 ms to 9,999 ms,
          Maximum error against the setting value: ±10% max.

          Control outputs

          PNP open collector 30 V, Residual voltage 1.2 V or less (Output current: 10 mA or less) / 2.2 V or less (Output current: 10 to 100 mA)
          (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less
          (Multiple connections) 1 output max: 20 mA or less

          Monitor output

          -

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*2

          Multiple connections to
          expansion units

          Up to 17 units can be connected in total (two-output type is treated as two units)

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference
          prevention units

          Connected to other than LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
          Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA*3

          Case size

          H 32.6 mm × W 9.8 mm × L 78.7 mm

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

          Power
          consumption

          Normal: 950 mW or less (at 30 V. 33 mA at 24 V, 60 mA or less at 12 V)*4
          Eco on mode: 815 mW or less (at 30 V. 29 mA at 24 V, 52 mA or less at 12 V)*4
          Eco Full mode: 650 mW or less (at 30 V. 24 mA at 24 V, 40 mA or less at 12 V)
          *5

          Environmental resistance

          Ambient temperature

          -20 to +55 °C (No freezing)*6

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Cable

          PVC

          Case

          Main unit and cover material: Polycarbonate

          Weight

          Approx. 65 g

          *1 80 µs cannot be selected when the LV-S31/S62/S63 is connected
          *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected.
          *3 These numbers double when "DOUBLE" is selected.
          *4 Increases 30 mW (1 mA) for High Speed mode.
          *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load.
          Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode.
          (1.15 × 860 mW × 1) + (1.15 × 860 mW × 2) = 2967 mW max.
          *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
          One or two more units connected: -20 °C to +55 °C ; 3 to 10 more units connected: -20 °C to +50 °C; 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.

          NOTE

          UL Listing(c/us)

          Contact us regarding a sensor head under UL Certification.