Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Amplifier Separate Type Photoelectric Sensor

          PS-N series

          Select Language

          Thrubeam type sensor head: General purpose

          Model

          PS-55

          PS-55C*3

          PS-05

          PS-58

          PS-52

          PS-52C*3

          PS-56

          Type

          Thrubeam, General purpose, Long-detecting distance

          Thrubeam, General purpose, Free-positioning

          Thrubeam, General purpose, Cylindrical

          Thrubeam, General purpose, Thin

          Detecting distance

          TURBO

          4,000 mm*1

          -

          600 mm*1

          -

          FINE

          2,000 mm

          300 mm

          Light source

          Infrared LED

          Smallest detectable object

          TURBO

          2.0 mm dia. opaque*2

          -

          0.3 mm dia. opaque*2

          -

          FINE

          1.0 mm dia. opaque*2

          0.5 mm dia. opaque*2

          0.3 mm dia. opaque*2

          Environmental resistance

          Enclosure rating

          IP64

          IP67

          -

          Ambient light

          Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max.

          Ambient temperature

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 30 g (Including cable)

          *1 For models with no specification, use FINE mode only.
          *2 With thrubeam sensors, the smallest detectable object indicates the size of a detectable object from the maximum detecting distance.
          *3 Models marked with a C are attached connector types.

          Thrubeam type sensor head: Environment-proof

          Model

          PS-201

          PS-201C*3

          PS-202

          Type

          Thrubeam, PFA-sheathed, Long-detecting distance

          Thrubeam, PFA-sheathed, Aperture-incorporated

          Detecting distance

          TURBO

          4,000 mm*1

          1,000 mm*1

          FINE

          2,000 mm

          500 mm

          Light source

          Infrared LED

          Smallest detectable object

          TURBO

          1.2 mm dia. opaque*2

          0.5 mm dia. opaque*2

          FINE

          0.8 mm dia. opaque*2

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max.

          Ambient temperature

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 40 g (Including cable)

          *1 For models with no specification, use FINE mode only.
          *2 With thrubeam sensors, the smallest detectable object indicates the size of a detectable object from the maximum detecting distance.
          *3 Models marked with a C are attached connector types.

          Diffuse-reflective sensor head

          Model

          PS-45

          PS-46

          PS-48

          PS-205

          PS-206

          Type

          Diffuse-reflective, General purpose, Long-detecting distance

          Diffuse-reflective, General purpose, Thin

          Diffuse-reflective, General purpose, Cylindrical

          Diffuse-reflective, PFA-sheathed, Long-detecting distance

          Diffuse-reflective, PFA-sheathed, Narrow-beam

          Detecting distance

          TURBO

          400 mm*1

          -

          400 mm*1

          -

          FINE

          200 mm

          100 mm

          25 mm

          200 mm

          70 mm

          Light source

          Infrared LED

          Red LED

          Detectable object

          Transparent and opaque

          Spot diameter

          -

          6 mm dia.
          (When detecting distance is 70 mm.)

          Hysterese
          (des Messabstands)

          15% max.

          10% max.

          20% max.

          15% max.

          Environmental resistance

          Enclosure rating

          IP64

          -

          IP67

          Ambient light

          Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max.

          Ambient temperature

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 30 g (Including cable)

          Approx. 40 g (Including cable)

          Approx. 60 g (Including cable)

          *1 For models with no specification, use FINE mode only.

          Definite-reflective sensor head

          Model

          PS-47

          PS-47C*2

          PS-49

          PS-49C*2

          Type

          Definite-reflective, General purpose, Small spot

          Definite-reflective, General purpose, Long-detecting distance

          Detecting distance

          TURBO

          -

          FINE

          10 mm (at centre)

          32 mm to 53 mm

          Light source

          Red LED

          Detectable object

          Transparent and opaque

          Smallest detectable object

          0.03 mm dia. copper wire*1

          0.1 mm dia. copper wire*1

          Spot diameter

          0.8 mm dia.
          (When detecting distance is 10 mm)

          1.5 mm dia.
          (When detecting distance is 50 mm)

          Hysterese
          (des Messabstands)

          3% max.

          6% max.

          Environmental resistance

          Ambient light

          Incandescent lamp: 4,000 lux max., Sunlight: 5,000 lux max.

          Ambient temperature

          -10 to +60 °C (No freezing)

          -10 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 30 g (Including cable)

          *1 With thrubeam sensors, the smallest detectable object indicates the size of a detectable object from the maximum detecting distance.
          *2 Models marked with a C are attached connector types.

          Amplifier: NPN

          Model

          PS-N11N

          PS-N12N

          PS-N11CN

          PS-N12CN

          PS-N10

          Type

          Cable

          M8 connector

          Zero line

          Output

          NPN

          -

          Main unit/Expansion unit

          Main unit

          Expansion unit

          Main unit

          Expansion unit

          I/O

          Control outputs

          1 output

          None*3

          External input

          1 input

          None

          1 input

          None

          Response time

          500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.

          Control output

          NPN open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max,
          residual voltage 1 V max. (when the out current is 10 mA or less)/2 V max. (when the output current is 10 to 100 mA)

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*1

          Unit expansion

          Up to 17 main units can be connected

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference prevention units

          4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)

          Case size

          H 32.6 mm × W 9.8 mm × L 78.7 mm

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

          Power consumption

          Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V)
          Eco on mode: 700 mW or less (at 30V. 24 mA max. at 24 V, 27 mA max. at 12 V) Eco Full mode: 490 mW or less (at 30V. 17 mA max. at 24 V, 20 mA max. at 12 V)

          Environmental resistance

          Ambient temperature

          -20 to +55 °C (No freezing)*2

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Case

          Main unit and cover material: Polycarbonate

          Cable

          PVC

          Weight

          Approx. 75 g

          Approx. 65 g

          Approx. 20 g

          *1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a uni t .
          One or two more units connected: -20 to +55 °C ; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C .
          *3 Counted as one output when added to a NU Series communication unit.

          Amplifier: PNP

          Model

          PS-N11P

          PS-N12P

          PS-N11CP

          PS-N12CP

          Type

          Cable

          M8 connector

          Output

          PNP

          Main unit/Expansion unit

          Main unit

          Expansion unit

          Main unit

          Expansion unit

          I/O

          Control outputs

          1 output

          External input

          1 input

          None

          1 input

          Response time

          500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

          Output selection

          LIGHT-ON/DARK-ON (switch-selectable)

          Timer function

          Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.

          Control output

          PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max,
          residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA)

          External input

          Input time 2 ms (ON)/20 ms (OFF) or more*1

          Unit expansion

          Up to 17 main units can be connected

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Number of interference prevention units

          4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)

          Case size

          H 32.6 mm × W 9.8 mm × L 78.7 mm

          Rating

          Power voltage

          24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

          Power consumption

          Normal: 860 mW or less (at 30 V. 30 mA max. at 24 V, 35 mA max. at 12 V)
          Eco on mode (ALL): 750 mW or less (at 30 V. 26 mA max. at 24 V, 28 mA max. at 12 V)
          Eco Full mode: 540 mW or less (at 30 V. 19 mA max. at 24 V, 21 mA max. at 12 V)

          Environmental resistance

          Ambient temperature

          -20 to +55 °C (No freezing)*2

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Material

          Case

          Main unit and cover material: Polycarbonate

          Cable

          PVC

          Weight

          Approx. 75 g

          Approx. 65 g

          Approx. 20 g

          *1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a uni t .
          One or two more units connected: -20 to +55 °C ; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C .