Recent Searches
    Series ()
      Models ()
        Keywords

          Multi-Purpose CCD Laser MicrometerIG series

          IG-010

          Sensor Head

          SPECIFICATIONS

          Select Language

          Model

          IG-010

          Operation principle

          CCD method

          Light source

          Wavelength

          660 nm (Visible light semiconductor laser)

          FDA

          Class 1*1

          IEC/JIS

          Class 1

          Mounting distance

          0 to 1000 mm

          Measurement range

          10 mm

          Sampling cycle

          980 µs (When the number of times for averaging is set to [hsp]: 490 µs)

          Minimum detectable object

          High sensitivity mode

          ø0.1 mm (Setting distance: 100 mm)*2

          Standard mode

          ø0.2 mm (Setting distance: 40 mm),
          ø0.5 mm (Setting distance: 500 mm)*2

          Repeatability

          5 µm (Setting distance: 100 mm)
          10 µm (Setting distance: 500 mm)
          80 µm (Setting distance: 1,000 mm)*3

          Linearity

          ±0.28 % of F.S. (±28 µm)*4

          Temperature characteristics

          ±0.03 % of F.S./°C (±3 µm/°C)*5

          Operation indicator

          Transmitter

          Optical axis alignment indicator: Green LED
          Power indicator: Green LED

          Receiver

          Optical axis alignment indicator: Green LED
          Position monitor: Dual bar LED (Red, Green)

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp: 5,000 lux, Sunlight: 5,000 lux*6

          Ambient temperature

          -10 to +45 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

          Material

          Case

          Zinc die-cast (Lower case), PBT (Upper case), Polyarylate (PAR) (Display part), SUS304 (Metallic part)

          Lens cover

          Glass

          Cable

          PVC

          Accessories

          Transmitter × 1, Receiver × 1, Sensor head cables (2 m) × 2

          Weight

          Approx. 380 g (including supplied items)

          *1 The classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
          *2 When the measurement target object is measured at the centre position of the setting distance.
          When the measurement mode is set to the glass edge mode, a glass edge of C0.1 mm or more can be detected (Setting distance: 500 mm).
          *3 When the light is shielded by half at the centre position of the setting distance. Vibration width when the average number of times is set to 16 and sampling is performed for 30 seconds.
          (When the analogue output is used, the margin of error of analogue output is added.)
          *4 When the setting distance is 100 mm and light is shielded at 50 mm position from the receiver. Margin of error to the ideal line.
          *5 When the setting distance is 100 mm and light is shielded by half at 50 mm position from the receiver.
          *6 Excluding when the average number of times is set to [hsp].

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

          Sensor Library

          • KEYENCE Information Network - CCD Laser Micrometer

          Sensors