Recent Searches
    Series ()
      Models ()
        Keywords

          High-Speed/Wide Area Static EliminatorSJ-F300 series

          SJ-F031

          Blower Type Main Unit, Wide

          SPECIFICATIONS

          Select Language

          Model

          SJ-F031

          Type

          Static elimination blower

          Voltage application method

          Variable DC

          Applied voltage

          ±7000 V max.

          Ion balance control method

          I.C.C. method

          Static elimination time

          Approx 2 sec.*1

          Ion balance

          ±5 V*1

          Maximum wind speed

          0.8 m/s*2

          Maximum air volume

          3.1 m3/min.

          Ozone density

          0.005 ppm max.

          Control input

          Input

          NPN open-collector or non-voltage contact signal

          Control output

          Alarm output

          NPN open-collector, 100 mA max. (40 V max.)

          Ion level alert output

          Condition alert output

          Rating

          Power voltage

          24 VDC ±10 %

          Current consumption

          1.2 A or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 65 % RH (No condensation)

          Weight

          Approx. 620 g

          *1 Measured at 300 mm from static elimination blower front surface (SJ-F030/F031, Air volume: MIN. SJ-F035/F036, Air volume: MAX)
          *2 Measured at 300 mm from static elimination blower front surface