Recent Searches
    Series ()
      Models ()
        Keywords

          Static Elimination SystemSJ-R series

          SJ-R132CA

          Bar Type Main Unit 1320 mm

          [Discontinued model]

          This model has been discontinued.

          Recommended Replaceable Products
          To contact us:

          SPECIFICATIONS

          Select Language

          Model

          SJ-R132CA

          Ion generation method

          Corona discharge method

          Structure

          Shockless resistor connection type

          Voltage application method/applied voltage

          Pulse AC method/±7000 V

          Ion balance control method

          I.C.C. method

          Ion balance

          ±30 V*1

          Operating distance

          50 to 2,000 mm

          Control input

          NPN open collector or non-voltage contact signal

          Control output

          NPN type photo relay: max. 100 mA (40 V or less)

          Air purge connection port

          M5

          Air purge supplied pressure

          0.2MPa or less

          Major features

          Ion level warning output, alarm output

          Rating

          Power voltage

          24 to 36 VDC ±10 %

          Overvoltage category

          I

          Pollution level

          2

          Current consumption

          250 mA (at 24 VDC)/150 mA (at 36 VDC)

          Environmental resistance

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Electrode probe

          Silicon

          Ground electrode

          Stainless steel

          Main body

          ABS resin

          Weight

          Standard controller/2-head controller

          Bar

          Approx 1,350 g

          *1 Operating distance: 600 mm (10 Hz), 1,500 mm (1 Hz). Ambient usage temperature: 0 to +50°C. Ambient usage humidity: 35 to 65%RH. This is the value measured with a 0.3 m/s downflow. (Contact KEYENCE for information on the ion balance with an ope