          LR-ZH490CB

          M18 threaded mount w/ M12 connector type, 490 mm

          SPECIFICATIONS

          Select Language

          Model

          LR-ZH490CB*1

          Type

          U.C.D. Function
          Distance based laser sensor

          Shape

          M18 Threaded mount

          Output

          NPN/PNP selectable

          Cable connection

          M12 connector, 4-pin

          Detectable distance

          25 to 490 mm (465 to 0)*2

          Standard detectable deviation

          25 to 170 mm: 9 mm
          170 to 290 mm: 25 mm
          290 to 390 mm: 40 mm
          390 to 490 mm: 50 mm

          Display resolution

          1 to 5 (1 to 5 mm)

          Spot diameter

          Approx. ø3 mm

          Response time

          1.5 ms / 10 ms / 50 ms selectable

          Light source

          Type

          Red laser (660 nm)

          Laser class

          Class 2 laser product (IEC60825-1)
          Class II Laser product (FDA (CDRH) Part1040.10)

          Function

          Indicator

          3-digit 7-segment display (white),
          output indicator (yellow),
          DATUM indicator (orange),
          1 spot indicator (green)

          Timer

          OFF/ON delay/OFF delay/One-shot

          Rating

          Power voltage

          10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

          Power consumption

          450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

          Specifications

          Control output

          NPN open collector/PNP Open collector selectable,
          Applied voltage 30 VDC or less, Control current 100 mA or less,
          Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

          Protection circuit

          Protection against reverse power connection, output overcurrent, output surge, reverse output connection

          Output operation

          Light-ON / Dark-ON selectable

          External input

          Input time calibration: 35 ms or more ON, 35 ms or more OFF
          Laser emission stop: 2 ms or more ON, 20 ms or more OFF
          Short-circuit current NPN: 1 mA or less/PNP: 2 mA or less

          Environmental resistance

          Enclosure rating

          IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*3, Diversey*3

          Insulation resistance

          20 MΩ or more (500 VDC)

          Ambient light

          Incandescent lamp: 10,000 lux or less
          Sunlight: 20,000 lux or less at 240 mm*4
          Incandescent lamp: 2,000 lux or less
          Sunlight: 4,000 lux or less at 490 mm*4

          Ambient temperature

          -10 to +50 °C (No freezing)

          Storage temperature

          -25 to +75 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Withstand voltage

          1,000 VAC, 50/60 Hz, 1 min

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          1,000 m/s2, 6 times in each of the X, Y, and Z directions

          Material

          Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
          Packing/Connector ring: FKM, Nut: SUS316L, Lock washer: SUS304

          Accessories

          Instruction Manual,
          FDA warning/certification/identification label,
          Laser warning/explanation labels

          Weight

          Approx. 75 g

          *1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. (LR-ZH490CB : Only when PNP output is selected.) You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office.
          *2 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
          *3 Have passed resistance tests with cleaning agents from multiple manufactures.
          *4 When the response time is 10 ms