          SPECIFICATIONS

          Select Language

          Model

          CB-EP100

          Type

          EtherNet/IPTM unit

          Compatible network

          EtherNet/IPTM and displacement sensor-specific protocols (socket communication)

          Ethernet

          Compliant standards

          IEEE 802.3 (10BASE-T), IEEE 802.3u (100BASE-TX)

          Transmission speed

          10 Mbps (10BASE-T), 100 Mbps (100BASE-TX)

          Transmission media

          STP or Category 3 or higher UTP (10BASE-T),
          STP or Category 5 or higher UTP (100BASE-TX)

          Maximum cable length

          100 m (Distance between the unit and Ethernet switch)

          EtherNet

          Maximum number of connectable hubs

          4 hubs (10BASE-T), 2 hubs (100BASE-TX)*1

          EtherNet/IPTM

          Supported functions

          Cyclic communication (Implicit messaging),
          Message communication (Explicit messaging),
          Compatible with UCMM and Class 3

          Number of connections

          64

          RPI

          0.5 ms to 10,000 ms (in 0.5 ms)

          Tolerable communication bandwidth for cyclic communication

          6,000 pps

          Message communication

          UCMM, Class 3

          Conformance test

          Compatible with Version A9

          Rating

          Power voltage

          24 VDC ±10 %, including Ripple (P-P)
          (supplied from the controller unit of the laser scanner)

          Current consumption

          0.12 A or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C

          Relative humidity

          20 to 85 % RH (No condensation)

          Weight

          Approx. 470 g

          *1 The number of connectable hubs is not limited when using a switching hub.

          Measurement Library

          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE (UK) Ltd Avebury House, 219-225 Avebury Boulevard, Milton Keynes MK9 1AU, U.K.
          Phone: +44 (0) 1908-696-900
          E-mail: ukinfo@keyence.co.uk
          Career Opportunities: KEYENCE Career Site

          Measurement Sensors