Amplifier Units Zero Line Type FD-ECA0

FD-ECA0 - Amplifier Units Zero Line Type

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • CSA

Specifications

Model

FD-ECA0

Type

Zero Line Type*1

No. of control outputs

*2

No. of analogue outputs

No. of external inputs

*2

Power supply cable

No cable

Response time (90% response)

50 ms/100 ms/250 ms/1 s/5 s (selectable, default 250 ms)*3

Input/output

Control output 1, 2

Analogue output

External input

Network compatibility

NU Series

No. of expansion units

8 units for one NU parent unit, 4 units for one
FS-MC8N/P parent unit*1

Protection circuit

Protection against head cable miswiring

Power supply

Power voltage

24 VDC±10% (including ripple), Class2/LPS

Power consumption

1290 mW (excluding load current)

Environmental resistance

Ambient temperature

-10 to +55°C (no freezing)*4

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions

Material

Main unit: Polycarbonate, FG terminals: copper/iron

Weight

Approx. 26 g

*1 The zero line type should be used by connecting to the FS-MC8N/P and NU Series.
*2 This counts as 2 outputs and 1 input when connecting multiple units to the FS-MC8N/P and NU Series.
*3 Analogue output response time is 5 ms additional and 63% response.
*4 The operating ambient temperatures for the adjacent number of cable type/M12 connector type units and the number of zero line type expansion units should be 55°C for 1 to 2 units, 50°C for 3 to 5 units, and 45°C for 6 to 8 units. The prescribed values for the ambient temperature assume that the amplifier unit has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.

Data Sheet (PDF) Other Models