Power-to-release Standard type NPN Standard cable 10 m GS-51N10

GS-51N10 - Power-to-release Standard type NPN Standard cable 10 m

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)
  • CSA

Specifications

Model

GS-51N10

Lock type

Power-to-release type

Type

Standard type

Output type

NPN

Response time

Lock

Lock→Unlock

220 ms *1*2

Unlock→Lock

220 ms *1*2*3

Lock

Locking force (Fzh)

Min. 2,000 N

Alignment tolerance of lock

±2 mm

Mechanical life-span

1 million cycles or more (with door operation speed of 1 m/s)

Acceptable operation frequency

1 Hz *4

Door radius

Min. 250 mm

Auxiliary release

Front, back *5

Cascading

Max. 25 units

Control output (OSSD output)

Output

Transistor outputs × 2

Max. load current

Max. 100 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m)

OFF state voltage

Max 2.0 V (with a cable length of 5 m)

Leakage current

Max. 0.5 mA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

AUX (Non-safety related output)

Output

Transistor output

Number of outputs

1

Max. load current

50 mA

Residual voltage (during ON)

Max 2.5 V (with a cable length of 5 m)

External input (Short-circuit current)

Safety input

Approx.1.5 mA × 2

Reset/EDM input

Lock control input

Approx. 2.5 mA × 1

OSSD operation switching input

Applicable Standards (Safety)

EN 61508, IEC 61508(SIL2/SIL3)
EN 62061, IEC62061(SIL CL2/SIL CL3)
EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4)
EN ISO14119(Type4)
IEC 60947-5-3, EN 60947-5-3
UL 61010-1, CAN/CSA-C22.2 No.61010-1

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Power supply

Power voltage

24 V DC ±20 % (Ripple P-P 10 % or less, Class2)

Current consumption

3.4 W *6

Environmental resistance

Enclosure rating

IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), Enclosure Type 3/4X/12/13 (NEMA250)

Operating ambient temperature

-20°C to +55°C (No freezing)

Storage temperature

-25°C to +70°C (No freezing) *7

Operating relative humidity

5% to 95% RH

Storage relative humidity

Vibration resistance

10 to 55 Hz, Double amplitude 2.0 mm, 5 minutes in each of the X, Y and Z directions (IEC 60947-5-3)

Shock resistance

30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)

Material

Sensor main unit

Case

SUS304, PPS, PBT, PAR, PA66, NBR

Lock

Aluminium alloy, Zinc die cast (Nickel chrome plating)

Cable

PVC

Actuator

Case

PPS, PBT, NBR

Lock

Aluminium alloy, SUS303

Weight

Approx. 770 g

*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1).
*2 If the OSSD operation is open/close link mode, Detect→ Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1)
*3 430 ms when locked at the same time the actuator is detected.
*4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF→ ON) = 3 mm, Sar(OFF→ ON) = 10.5 mm.
*5 Do not apply excessive torque (0.45 N·m or higher).
*6 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification.
*7 When stored for a long period of time, please store it at a temperature of 55°C or lower.

Data Sheet (PDF) Other Models