Digital Fibre Optic Sensors

FS-N series

Catalogues View Catalogue

Specs Digital Fibre Optic Sensors FS-N series

Main unit: NPN

Model

FS-N11N

FS-N12N

FS-N11CN

FS-N12CN

FS-N13N

FS-N14N

FS-N11MN

Image

Type

Standard 1 output
Cable

Standard 1 output
M8 connector*3

High functionality 2 output
Cable

Monitor output
Cable

Output

NPN

Main unit/Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Control output

1
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

2
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

1
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

Monitor output (1-5 V)

-

1

External input

-

1
Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)

-

Light source

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Unit expansion

Up to 16 units can be connected total (two output type is treated as two units)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1
Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1
Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 75 g

Approx. 45 g

Approx. 22 g

Approx. 80 g

Approx. 70 g

Approx. 75 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55 °C; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C. When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
*3 Use a cable length of 30 m or less for M8 connector types.

Back to top

Main unit: PNP

Model

FS-N11P

FS-N12P

FS-N11CP

FS-N12CP

FS-N13P

FS-N14P

FS-N13CP

FS-N14CP

Image

Type

Standard 1 output
Cable

Standard 1 output
M8 connector*3

High functionality 2 output
Cable

High functionality 2 output
M8 connector*3

Output

PNP

Main unit/Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Main unit

Expansion unit

Control output

1
PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

2
PNP open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

External input

-

1
Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)

-

Light source

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Unit expansion

Up to 16 units can be connected total (two output type is treated as two units)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V)*1
Eco on mode: 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V)*1
Eco Full mode: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

Normal: 1050 mW or less (42 mA max. at 24 V, 56 mA max. at 12 V)*1
Eco on mode: 950 mW or less (38 mA max. at 24 V, 47 mA max. at 12 V)*1
Eco Full mode: 600 mW or less (24 mA max. at 24 V, 29 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 75 g

Approx. 45 g

Approx. 22 g

Approx. 80 g

Approx. 70 g

Approx. 22 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55 °C; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C. When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.
*3 Use a cable length of 30 m or less for M8 connector types.

Back to top

Main unit: 1 output type

Model

FS-N15CN

FS-N15CP

Image

Type

1 output type

Output

NPN

PNP

Input/Output configuration

M8 connector *1

Main unit/Expansion unit

Main unit

Control output

1 output
NPN open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or less

1 output
PNP open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or less

External input

1 input
Input time 2 ms (ON)/20 ms (OFF) or more, when selecting External calibration 25 ms (ON/OFF) or more

Output toggle

LIGHT-ON/DARK-ON (switch-selectable)

Light source

Red, 4-element LED (Wavelength: 630 nm)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer

Response time

50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Number of interference prevention units

0 units (connection not possible)

Case dimensions

H30.3mmxW9.8mmxL71.8mm

Unit expansion

0 units (expansion not possible)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V) *2
Econ on (ALL): 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V) *2
Eco full: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Normal: 950 mW or less (39 mA max. at 24 V, 52 mA max. at 12 V) *2
Eco on (ALL): 850 mW or less (35 mA max. at 24 V, 44 mA max. at 12 V) *2
Eco full: 520 mW or less (21 mA max. at 24 V, 26 mA max. at 12 V)

Environmental resistance

Enclosure rating

IP66*3*4

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Main unit: glass-reinforced PBT; Cover: Sulfonic resin

Material

Adapter

Glass-reinforced PBT

Weight

Approx. 30 g

*1 Use a cable of 30 m or less.
*2 When the Power Mode is set to HIGH SPEED, 100 mW (4.0 mA) will be added.
*3 About the enclosure rating when a small-diameter fibre unit (the diameter of the cable is ø1.3 or ø1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used. When any small-diameter fibre units except for the above are used, IP65 is applied.
*4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied.
When the Fibre Unit and KEYENCE's M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.Then retighten it as much as 1/16-1/8 of a rotation with pliers.)
When the Fibre Unit and KEYENCE's M8 connector cable are not connected
When the dust cover of the Sensor Amplifier is open
When there is debris in the dust cover
When the waterproof adapter A/B are not used at the time of installation of a small-diameter fibre unit.

Back to top