          Ultra-small Digital Laser SensorLV-S series

          LV-12SBP

          Amplifier Unit, Expansion Unit, PNP

          SPECIFICATIONS

          Select Language

          Model

          LV-12SBP*1

          Type

          Expansion unit (1 line)

          Output

          PNP

          Control output

          PNP open-collector x 2 ch 30 VDC max. 100 mA max. per output

          Response time

          ExceptLV-S31

          ULTRA

          4 ms

          SUPER

          2 ms

          TURBO

          500 µs

          FINE

          250 µs

          HSP

          80 µs

          LV-S31standard mode

          500 µs

          LV-S31standard mode

          SPED2

          2 ms

          SPED3

          8 ms

          SPED4

          32 ms

          LV-S31High-speed mode

          250 µs

          Control input

          Light emission stop input, external calibration, set value bank selection input, or shift input

          Number of interference prevention units

          ULTRA

          4*2

          SUPER

          TURBO

          2*2

          FINE

          HSP

          0*2

          Unit expansion

          Up to 16 expansion units can be installed (17 units including the main unit)*3

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*4

          Power consumption

          Normal

          1.7 W max. (70 mA max. for 24 V)

          Ratings

          Eco-Half Eco-All

          1.55 W max. (65 mA max. for 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C (No freezing)*5

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

          Material

          Main unit

          Main body, cover: Polycarbonate

          Weight

          Approx. 80 g (including 2 m cable)

          *1 LV-S62 and LV-S63 can ONLY be used with amplifiers ending with B or BP.
          *2 Numbers for the LV-S31 are four in standard mode and two in high-speed mode.
          *3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows:
          1 to 2 units connected: -10 to +55ºC (14 to 131ºF)
          3 to 10 units connected: -10 to +50ºC (14 to 122ºF)
          11 to 16 units connected: -10 to +45ºC (14 to 113ºF)
          *4 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % max.
          *5 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C