Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Important notice for our customers (Covid-19 related)
          Latest information on delivery and product/application inquiry support
          1. Home
          2. Products
          3. Sensors
          4. Inductive Proximity Sensors
          5. Separate Amplifier Proximity Sensor
          6. Models
          7. Amplifier Unit, Expansion Unit, PNP

          Separate Amplifier Proximity SensorES series

          Amplifier Unit, Expansion Unit, PNP

          ES-M2P

          SPECIFICATIONS

          Select Language

          Model

          ES-M2P*1

          Type

          One-line expansion system

          Shape

          Expansionunit

          Operation mode

          N.O./N.C. (switch-selectable)

          Timer function

          10-ms delay / timer OFF switchable*2

          Output

          PNP

          Output

          Control output

          PNP open collector 100 mA max.
          26.4 V, residual voltage 1 V max.

          Disconnection alarm output

          *3

          Response time

          1 ms max.

          Temperature characteristics

          Within ±8% of detecting distance at 23°C
          when within 0 to 50°C temperature range

          Sensitivity adjustment

          25-turn trimmer

          Protection circuit

          Reverse power connection protection, output
          overcurrent protection, output surge protection

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less

          Current/power consumption

          25 mA max.

          Environmental resistance

          Ambient temperature

          0 to +50 °C*4

          Relative humidity

          35 to 85 % RH (No condensation)

          Weight

          Approx. 35 g (including nuts and 2-m cable)

          *1 The ES-M1(P)/M2(P) cannot be connected to the EH-422, 430, 440 or 290.
          *2 During N.O. operating configuration, the off delay timer is 10 ms. During N.C., the on delay timer is 10 ms.
          *3 Broken connection warning output is not available on the ES-M2(P).
          *4 The ambient temperature changes according to the fo llowing conditions when expansion units are added. When adding units, always attach them to a DIN rail (metal plate) and set the output current to 20 mA or less.
          1 to 10 expansion units: 0 to +50 °C
          11 to 16 expansion units: 0 to +45 °C

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE (UK) Ltd Avebury House, 219-225 Avebury Boulevard, Milton Keynes MK9 1AU, U.K.
          Phone: +44 (0) 1908-696-900
          E-mail: ukinfo@keyence.co.uk
          Career Opportunities: KEYENCE Career Site

          Sensors