Bar Type Main Unit, Standard Model 3000 mm SJ-H300A

SJ-H300A - Bar Type Main Unit, Standard Model 3000 mm

  • CE Marking
  • CSA

Specifications

Model

SJ-H300A

Type

HA

Ion generation method

Corona discharge method

Structure

Shock-proof, resistance-coupled type

Voltage application method/applied voltage

Pulse AC method/±7,000 V

Ion balance control method

Dual I.C.C.

Ion balance

±30 V*1

Operating distance

50 to 2,000 mm

Control input

NPN open collector or non-voltage contact signal

Control output

NPN type photorelay, 100 mA max. (at 40 V max.)

Major functions

Condition alarm output, ion level alarm output, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less

Effective length

3,000 mm*2

No. of electrodes

48

Static elimination bar length

2,960 mm

Rating

Power voltage

24 to 36 VDC ±10 %

Current consumption

500 mA (at 24 VDC)/350 mA (at 36 VDC)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main unit

ABS resin/PC

Weight

Static elimination bar

3,150 g

*1 The value is measured under the following condition.
*2 The effective length is determined based on the static elimination range at a distance of 50 mm.

Data Sheet (PDF) Other Models