          CA-U5

          SPECIFICATIONS

          Select Language

          Model

          CA-U5

          Input conditions

          Rated input voltage

          100 to 240 VAC (85 to 264 VAC, 110 to 370 VDC)*1

          Efficiency

          82%/85% typ. (100/200 VAC) (with 100% load)

          Rated input current

          3.9 A/1.8 A max. (100/200 VAC)

          Output conditions

          Rated output voltage

          24V DC

          Rated output current

          12.5 A

          Protection

          Overvoltage protection

          Constant current voltage limiting. Automatic reset
          15.6 A min.

          Activates when the voltage reaches 26.4 V or more. Voltage turn-off.
          Operation resumes when the input power is turned on again.*2

          Applicable standards

          Safety standards

          UL : UL508, UL60950-1
          C-UL : CSA C22.2 No.14-M95, CSA C22.2 No.60950-1-03
          EN : EN62368-1, EN50178
          IEC : IEC62368-1

          EMC standard

          FCC Part15B ClassA, EN55011 ClassA, EN61000-6-2

          Limits for harmonic current emissions

          EN61000-3-2

          Environmental resistance

          Ambient temperature

          –10 to +55ºC, No condensation

          Storage temperature

          –20 to +70ºC, No condensation

          Relative humidity

          25 to 85%, No condensation

          Weight

          Approx. 1540g

          *1 For conforming to safety standards shown above, rated input voltage is 100 to 240 VAC 50/60 Hz.
          *2 To reset the unit, turn off the input power once, wait for 1 minute or more, and then turn on the input power again.

          Measurement Library

          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE (UK) Ltd Avebury House, 219-225 Avebury Boulevard, Milton Keynes MK9 1AU, U.K.
          Phone: +44 (0) 1908-696-900
          E-mail: ukinfo@keyence.co.uk
          Career Opportunities: KEYENCE Career Site

          Measurement Sensors