Flow and Pressure Dual Sensor

FD-EP series

Catalogues View Catalogue

Sensor head Pipe outer diameter ø10 FD-EPH10

FD-EPH10 - Sensor head Pipe outer diameter ø10

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • CSA

Specifications

Model

FD-EPH10

Supported pipe diameter

Pipe outer diameter

ø10 *1

Applicable outer diameter range

Polyurethane

10.0 ±0.15 mm

Nylon

10.0 ±0.08 mm

Pipe materials

Plastic piping that can be connected to one-touch couplings

Supported fluids

Air, nitrogen, argon, non-corrosive gases*2

Supported fluid temperatures

−10 to +60°C

Pressure resistance

1 MPa

Flow detection principle

Transmission time difference method

Flow specifications

Rated flow

(volumetric flow)

150 L/min

(at 20°C, atmospheric pressure) *Initial display

Gas at 20°C, 0.0 MPa

Gas at 20°C, 0.2 MPa

450 L/min

Gas at 20°C, 0.4 MPa

750 L/min

Gas at 20°C, 0.6 MPa

1050 L/min

Measurement accuracy

±(2.0% of RD+1.0% of F.S.)*3*4

Repeatability

2.5% of F.S. at 250 ms response time*3*5

Pressure specifications

Rated pressure

-100 kPa to +0.75 MPa *However, flow cannot be measured in the -100 to -30 kPa range.

Overall accuracy

±2.0% of F.S.*3

Repeatability

2.5 ms response time: ±0.4% of F.S.

Display resolution

Instantaneous flow

0.1/1 L/min

Integrated flow

0.1/1/10/100/1000 L

Pressure

0.1/1 kPa

Environmental resistance

Enclosure rating

IP65 (IEC60529)

Ambient temperature

-10 to +60°C (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions

Material

Sensor body (part not in contact with fluids)

PBT/PAR/Iron/Brass/POM/NBR/Stainless steel/Aluminium

Flow path (part in contact with fluids)

PBT/Brass/NBR/Nylon

Weight

Approx. 180 g

*1 For stable detection, a pipe inner diameter equal to or greater than the inner diameter of this product is recommended.
*2 The gas through which ultrasonic waves penetrate. Readings may become unstable depending on the pipe’s internal pressure and the type of gas.
*3 This is the guaranteed value from verification performed at KEYENCE inspection facilities. Errors may occur according to the type and condition of the customer’s pipes, the type of fluid, the fluid temperature, and other factors.
*4 The definition assumes that the flow velocity distribution is stable with a sufficient straight pipe segment. Does not include pulsations or changes in flow speed distribution caused by equipment.
*5 Accuracy improves with longer response times. As a rule, this is by a proportion of √(250 ms/response time)x.