          FU-55

          SPECIFICATIONS

          Select Language

          Model

          FU-55*1

          Optical axis diameter
          (Standard target to be detected)

          ø0.125 mm

          Size

          ø2.5 mm

          Fibre unit length

          50 cm cannot be cut

          Minimum bend radius

          R10 mm

          Minimum detectable object

          Object with a diameter of 0.005 mm*2

          Environmental resistance

          Ambient temperature

          -40 to +70 °C

          Weight

          Approx. 3 g

          *1 For details on the detecting distance, see the fibre amplifier catalogue.
          *2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.